MGD-100

MGD-100

Scalable Gas Detection System

  • Infrared or semiconductor sensor options
  • System solution for 1, 2, 4 or 6 sensors
  • Detects refrigerants, CFC, HCFC, HFC, Ammonia, Carbon Dioxide and combustible gases
  • IP66 housing options, including remote and duct mount sensors
  • Built-in relay for 1 or 2 pre-set alarm levels

Description

The MGD-100 is an affordable and scalable gas detection system used to provide real-time monitoring of refrigerant and combustible gases, ammonia and carbon dioxide. The unit alarms when pre-set thresholds are exceeded. Alarms are monitored by a centralized controller, which can alert personnel of potential hazardous conditions via an onboard buzzer and LED alarm indicators.

The unit can be configured from single-sensor, one-alarm level system to larger scale systems consisting of 6 sensors with 2 alarm levels. The instruments are connected to and powered by the MGD controller. A variety of housing options are available including IP41 and IP66 rated enclosures, which enable direct placement of the MGD-100 in a variety of environments. For special applications, the sensor can be remotely mounted from the instrument.

Specifications

 
Type Gas detector using IR or semiconductor sensor
Gases Refrigerants:
Ammonia (NH3), Carbon Dioxide (CO2), Hydrocarbons, and HFCs, HCFCs, CFCs
Combustible gases:
Methane (CH4), Propane (C3H8), Butane (C4H10), LPG, and Hydrogen (H2)
Measuring Range * ppm, %LEL or Vol%
Status Indicators 1 alarm system green and red LEDs
2 alarm system green, yellow and red LEDs
Power Supply 12 VDC or 100-230 VAC 60 / 50 Hz
Distance of Sensor from Controller 1 or 2 sensor 200 ft (60 m); 4-wire
4 or 6 sensor 500 ft (150 m); 4-wire
Audible Alarm Buzzer
Relay * 1 or 2 alarm relay, SPDT
Rating 10 A @ 120 / 230 VAC, resistive load
Ambient Conditions* Temperature       IP41 - 4 to +122 °F (- 20 to +50 °C)
                            IP66 - 40 to +122 °F (- 40 to +50 °C)
Humidity             0 to 95 %RH, non condensing
Altitude               0 to 10,000 ft (3,050 m)
Controller Enclosure powder coated aluminum, M20 cable gland, IP51
Size (w x h x d)
Approx.
1 or 2 sensors 4.1” x 8.4” x 3.2” / 105 x 215 x 85 mm
4 or 6 sensors 10.4” x 10.3” x 3.3” / 265 x 265 x 85 mm
Weight Approx. 1 or 2 sensors 2.9 lbs / 1.3 kg
4 or 6 sensors 5.7 lbs / 2.6 kg 
Instrument Enclosure ABS; M20 cable gland
Size (w x h x d)
Approx. *
IP41 3.4” x 5.6” x 2.1” (90 x 145 x 55 mm)
IP66 6.5” x 6.9” x 3.3” (165 x 175 x 85 mm)
Ex d 5.2” x 6.3” x 3.6” (135 x 160 x 95 mm)
Weight Approx.* IP41 6.3 oz (180 g)
IP66 22 oz (623 g)
Ex d 9.3 lbs (4.2 kg)
Approvals CE, UL, CSA, IEC, EN 61010-1  

* See datasheet for details

Visitors: 174,327